Comment by Louis Place on September 4, 2012 at 2:31pm

yes, the therapy jets are the filter jets :)

Comment by Louis Place on September 4, 2012 at 2:29pm

it is the blower ring in the bench that you see creating all the turbulence in the water. We use 1.5" flex pipe that we sink into a trench in the bench and there are about 15 air nozzles that allow air to flow out from the bench. The nozzles are flush with the bench...

Comment by Louis Place on September 4, 2012 at 2:26pm

Yes, frame and grate on the spa. There are 3 returns in the pool and the spa has 6 waterway jets with an external air intake. We usually use a 1.5 HP, but I think we did a 2HP on this one to improve the water flow over the spa edge. Typically all you need is 1.5 HP for 6 jets or less. I believe there is only one other pump used for the fountains. We did another one that is about to featured in the next edition of Home Trends Magazine and this one has over 13 jets and the spa is 6.5' x 15' wide rectangle, zero spillover edge... It is awesome, we used the Waterway 3 and 4 jets packs for the back and calve areas

Comment by Brandon Ruland on September 4, 2012 at 2:23pm

Oh ok you use the Therapy Jets as the Filter Jets because of the GVA Actuator Valve.  

Comment by Brandon Ruland on September 4, 2012 at 2:22pm

Did you use frame and grate's or Sumps in the Spa?  How many filter jets in the spa?  how many Therapy Jets in that spa?  And what HP pump did you use for the Filtration for the Pool/Spa?  Did you use a total of 3 Pumps including the 2 Booster Pumps?

Comment by Louis Place on September 4, 2012 at 2:04pm

The pool and spa both run on the same pump, and there are booster pumps for the fountains. When you go into "spa mode" this turns vales that isolate the spa from the pool. The same pump that is used to filter and circulate the pool water is used to take water from the spa and return it back into the spa through the therapy jets.  The main reason why you would want more than one pump is so you can heat the spa and run the fountains separately at the same time.  

Comment by Brandon Ruland on September 4, 2012 at 12:35pm

Is this a Combination Pool and Spa System or is it One system with an actuator Valve for heat?

Sign in

E-mail

Password
 or Sign Up
By signing in, you agree to the amended Terms of Service and Privacy Policy.
Forgotten your password?

Events

Latest Activity

kevox712 is now a member of Pool Genius Network
yesterday
Kim Skinner commented on Kim Skinner's blog post Plaster Finishes Should Last 20 Years
"Thanks Kevin, I like hearing that there are good plaster companies out there, and that they do good…"
Monday
Kevin Misley commented on Kim Skinner's blog post Plaster Finishes Should Last 20 Years
"Great info Kim. My plaster contractor will tent my pools if any threat of rain is present and also…"
Sunday
Lyle Watson replied to Ben Jewell's discussion Open Pit DE Vacuum Filters
"I worked on several of these systems, many, many years ago. Are you still seeking…"
Friday
Richard A. Falk commented on Richard A. Falk's group Water Chemistry
"Thanks Lester.  This is actually the second time they ran the article describing the history…"
Feb 12
Lester Eric Brehm commented on Richard A. Falk's group Water Chemistry
"Congratulations for getting some credit for your work on CYA in Service Industry News ! !"
Feb 12
Kevin Misley replied to John McGehee's discussion Issues with using rainwater for everything pool construction and maintenance related
"John About 7-8 years ago, I was asked by a GC to bid on a project whereas a college was expanding…"
Feb 12
Kim Skinner posted a blog post

Plaster Finishes Should Last 20 Years

All pool plaster finishes should last 20 years or more. However, some last only 5 to 7 years, and…See More
Feb 11

© 2019   Created by PGN Admin.   Powered by Pool Genius Network

Badges  |  Report an Issue  |  Terms of Service

Offline

Live Video